Instruction Manual:
Overview:
The Pediatric Intraosseous (IO) Leg Trainer is designed for healthcare professionals to practice intraosseous injection techniques in a pediatric setting. This realistic simulator replicates the tibia and patella anatomy, providing hands-on training for needle insertion, infusion, and fluid flashback.
Set-Up Instructions:
Step 1: Loosen (but do not remove) the bone's vent cap to allow air to escape during filling.
Step 2: Attach a syringe pre-filled with simulated blood (red liquid) to the trainer.
Step 3: Inject the liquid into the bone. Once fluid emerges from the port, tighten the vent cap.
Step 4: Place the skin cover over the leg.
Step 5: Begin intraosseous injection practice.
Step 6: After removing the IO needle, seal the needle site with wax to prevent leakage.
Bone Replacement Instructions:
Unscrew the bone connector to remove the used bone. Insert a new bone and securely tighten the connector to ensure stability.
Cleaning & Maintenance:
-
Withdraw any remaining liquid from the bone using a syringe.
-
Flush the cavity with clean water by injecting and withdrawing repeatedly.
-
Clean the trainer's surface with water or wet wipes.
-
Allow the model to dry thoroughly before storing.
-
Keep away from high temperatures and direct sunlight.
Safety Guidelines:
-
For simulation training only. Do not use on humans or animals.
-
Use only the accessories provided for this trainer.
-
Keep simulated blood powder out of children's reach and avoid ingestion.